# Axial Fan Evaporative Air Cooler

This is the **axial-fan family overview**: RDF18, RDF20/SF, RDF23, RDF26 PMSM, RDF30 and RDF36 platforms delivering **18,000-36,000 m3/h** at 1.1-3.0 kW. Axial fans move a lot of air at low resistance - the efficient, economical choice for free discharge, short socks and wall/roof positions that make up most factory ventilation projects.

## Why factories choose RDF evaporative cooling

- **Proven cooling pad.** 100 mm Type-5090 cooling pad with evaporation efficiency above 80%; corrugated cellulose gives roughly 100x the water-to-air heat-exchange area of a flat surface.
- **Real temperature drop.** 4-10 C cooler supply air in humid climates and 4-15 C in hot, dry climates, with continuous fresh air instead of recirculated indoor air.
- **About 1 kWh per hour.** A typical RDF unit uses roughly one unit of electricity per hour - about one fifth of the capital cost and one tenth of the running cost of compressor air conditioning for the same area (manufacturer figures).
- **Clean, low-maintenance water system.** Open water distribution is easy to inspect and resists clogging; Class-I anti-algae pad treatment, low-water protection and RoHS/REACH compliant contact materials.
- **Pick airflow to match the bay:** 18k for standard workshops, 20k SF PMSM for extra volume at 1.1 kW, 23k/26k for wide high bays, 30k/36k for heavy heat loads and dense occupancy.
- **Same chassis logic across the range** - A/B/C discharge, shared pad, panel and water-system architecture, so mixed sites are easy to operate and maintain.

## Technical specifications

| Model | Voltage | Max. airflow (m3/h) | Current | Power (kW) | Dimensions (mm) | Weight (kg) | Tank (L) |
| ----- | ------- | ------------------- | ------- | ---------- | --------------- | ----------- | -------- |
| RDF18A-11 | 380V/50Hz | 18,000 | 2.8 A | 1.1 | 1100x1100x1000 | 60 | 25 L |
| RDF20A/SF | 220V/50Hz | 20,000 | 3.7 A | 1.1 | 1100x1100x1000 | 53 | 35 L |
| RDF23A-11 | 380V/50Hz | 23,000 | 3.7 A | 1.5 | 1100x1100x1300 | 70 | 25 L |
| RDF26A/F1 (PMSM) | 220V/50Hz | 26,000 | 5.8 A | 1.5 | 1100x1100x1300 | 63 | 25 L |
| RDF30A-11 | 380V/50Hz | 30,000 | 5.2 A | 3.0 | 1320x1320x1200 | 92 | 65 L |
| RDF30C-11 | 380V/50Hz | 30,000 | 5.2 A | 3.0 | 1320x1320x1200 | 92 | 65 L |
| RDF36A | 380V/50Hz | 36,000 | 6.5 A | 3.0 | 1500x1500x1400 | 170 | 65 L |
| RDF36C | 380V/50Hz | 36,000 | 6.5 A | 3.0 | 1500x1500x1400 | 170 | 65 L |

Representative axial configurations, 18,000-36,000 m3/h. Side (A), bottom (B) and top (C) discharge versions exist for every platform; sub-model detail is on the respective series pages.

## Axial vs centrifugal: which family?

Choose axial for direct blow, wall mounting, rooftop free discharge and fabric-sock systems - the large majority of evaporative-cooling installations. Choose the [centrifugal B-series](/product/centrifugal-fan-evaporative-air-cooler/) when the design includes long metal ducts, HEPA or activated-carbon stages, elbows and dampers - all of which consume static pressure an axial fan does not have.

The table shows representative axial configurations; the complete sub-model tables (LCD/LED, 220/380 V, A/B/C) live on the RDF18, RDF23 and RDF26 series pages linked below.

## Backed by a specialist air-treatment manufacturer

- 20+ years focused on evaporative cooling and large industrial fans; National High-Tech Enterprise and CRAA-listed manufacturer.
- Deputy Director Unit of the national evaporative-cooling industry committee, with 40+ patents and self-developed, patented molds.
- Product liability underwritten by CPIC (policy ADNGD0207121Q000109N); type-test, protection-grade and CE motor-conformity documentation supplied with export orders.
- RDF equipment is published in service with automotive, food and electronics manufacturers including SAIC-GM-Wuling, FAW-Volkswagen, GAC Toyota/Honda, PepsiCo, Foxconn, Panasonic, Gree, Midea and Haier.

## Ordering the axial-fan evaporative air cooler (RDF18-RDF36, 18,000-36,000 m3/h)

- **MOQ:** 10 units
- **Lead time:** 10 units ex stock; 100 units in about 7 days; 500 units in about 20 days (larger orders confirmed case by case)
- **Trade terms:** FOB Shenzhen
- **Payment:** T/T - 35% deposit, 65% balance paid before shipment
- **Warranty:** 2-year warranty on the complete unit per the factory's warranty policy: motor 2 years, controller 2 years, cooling pad 2 years, water pump 1 year. Overseas spare-parts support (wear-parts list, quotation and dispatch lead time) is confirmed with your order.
- **Documentation:** Factory inspection reports, RoHS/REACH pad-compliance documentation and the evaporative-cooler design patent certificate are available. Complete-unit CE/SASO certificates can be arranged for export orders upon request; motor-level CE (LVD), EMC/RoHS reports and national-lab complete-unit inspection reports are on file.

Send your floor dimensions, ceiling height and heat-load description (a sketch or photo is enough) - we reply with a model recommendation, layout and quotation within one business day via the [contact page](/contact/).

## Frequently asked questions

### How much can an evaporative cooler lower the temperature?

Brochure figures are 4-10 C in humid climates and 4-15 C in hot/dry climates. The closer the outdoor air is to saturation, the smaller the drop - ventilation benefit remains. We size from your local temperature and humidity data.

### Does it work when it is humid?

Yes - the mechanism shifts toward ventilation and air movement. The large fresh-air volume keeps workshops acceptable even at 70-80% RH; for sealed spaces the compressor-based RDF low-carbon range is the alternative.

### Which size sells most?

The RDF18 (18,000 m3/h) is the volume platform - one unit covering roughly 100-150 m2 of typical workshop suits most factories. Projects move up the table when ceiling height, heat load or occupancy is unusual.

### Are all axial models available in single phase?

Most platforms offer both 380 V three-phase and 220 V single-phase (BT); the large 30k/36k units are three-phase machines. Check the model row or ask us to confirm for your site supply.

### How much water and electricity does it use?

Power is roughly 1 kWh/h for the 18,000-26,000 m3/h axial platforms; water use varies with humidity and bleed settings. Nominal water consumption per the manufacturer's Chinese-market data: about 60 L/h for the 18,000 m3/h class and about 100 L/h for the 23,000 m3/h class.

### How often must the cooling pad be replaced?

With normal water quality and Class-I anti-algae treatment the 5090 cellulose pad lasts multiple seasons; replacement is a tool-free panel job. Maintenance schedule and pad pricing ship with the quotation.

## Related products

- [RDF 18 Series - Side Discharge](/product/rdf-18-series-evaporative-air-cooler-side-discharge/)
- [RDF 23 Series - Top Discharge](/product/rdf-23-series-evaporative-air-cooler-top-discharge/)
- [RDF 26 Series Evaporative Air Cooler](/product/rdf-26-series-evaporative-air-cooler/)
- [Centrifugal Fan Evaporative Air Cooler](/product/centrifugal-fan-evaporative-air-cooler/)

## More from TierCooling

- [View installed project references](/projects/)
- [About the manufacturer](/about/)
- [All products in this category](/product-category/evaporative-air-coolers/)

## FAQ

### How does an evaporative air cooler work?

Evaporative cooling pulls hot outside air through water-wetted pads; evaporation removes heat from the air, delivering cooled airflow into the space. It works best in hot, dry climates where the evaporation effect is strongest.

### What is the difference between side, top and bottom discharge?

Discharge direction decides installation: side-discharge units mount on walls and blow across or into ducting, top-discharge units suit roof mounting with downward delivery, and bottom-discharge variants feed airflow through a raised plenum. The right choice depends on building structure and airflow path.

### What maintenance does an evaporative cooler need?

Routine care means keeping the pads and water system clean, checking the pump and drain, and winterising the unit in cold regions. Maintenance frequency rises with dust levels in the workshop.

### Do evaporative coolers work in humid climates?

Cooling effect depends on the gap between air temperature and wet-bulb temperature, so output drops in very humid weather. In mixed climates they are often sized as part of a hybrid system with HVLS fans or low-carbon air conditioning.