# HVLS Fans for Markets & Malls

Comfort in a supermarket, wholesale market, mall atrium or exhibition hall has to be invisible: silent, draught-free and completely safe above crowds. RDF **HVLS fans for markets and malls** cover circles of O 20-44 m from a single 0.66-1.3 kW gearless motor at **under 39 dB(A)**, mixing conditioned or ventilated air evenly over shoppers and stalls.

## Why projects specify this RDF HVLS fan

- **Quiet enough for retail.** Below 38-39 dB(A) - customers hear the ambience, not the fan.
- **Public-space safety package.** Six T6-tempered anodised Al-Mg blades on a 45# steel petiole, the patented triple-bolt starfish-claw anti-drop hub and a secondary safety cable.
- **Lower air-conditioning cost in atria.** Mixing stratified air in tall voids means cooled air reaches the trading floor instead of pooling at the roof.
- **Humidity and condensation control** in fresh-food and wet-market zones where roofs and cold-rack fronts otherwise sweat in humid months.
- **Clean, oil-free appearance.** The gearless direct drive has no oil seal to leak above merchandise or food displays.

## Technical specifications

| Model | Diameter | Power supply | Current | Power | Max. speed | Max. airflow | Noise | Net weight | Coverage |
| ----- | -------- | ------------ | ------- | ----- | ---------- | ------------ | ----- | ---------- | -------- |
| RDF-S3600 | 3,600 mm (12 ft) | 220V/50Hz, 1-phase | 3.0 A | 0.66 kW | 90 rpm | 4,522 m3/min | <38 dB | 72 kg | O 20-24 m |
| RDF-S4200 | 4,200 mm (14 ft) | 220V/50Hz, 1-phase | 3.0 A | 0.66 kW | 80 rpm | 5,306 m3/min | <38 dB | 75 kg | O 22-26 m |
| RDF-S5200 | 5,200 mm (17 ft*) | 220V/50Hz, 1-phase | 3.0 A | 0.66 kW | 70 rpm | 7,065 m3/min | <39 dB | 78 kg | O 25-30 m |
| RDF-B6200 | 6,200 mm (20 ft) | 220V/50Hz, 1-phase | 4.4 A | 1.3 kW | 65 rpm | 10,747 m3/min | <39 dB | 100 kg | O 32-37 m |
| RDF-B6200 | 6,200 mm (20 ft) | 380V/50Hz, 3-phase | 3.0 A | 1.3 kW | 65 rpm | 10,747 m3/min | <39 dB | 100 kg | O 32-37 m |
| RDF-B6700 | 6,700 mm (22 ft) | 220V/50Hz, 1-phase | 4.4 A | 1.3 kW | 60 rpm | 12,560 m3/min | <39 dB | 105 kg | O 35-40 m |
| RDF-B6700 | 6,700 mm (22 ft) | 380V/50Hz, 3-phase | 3.0 A | 1.3 kW | 60 rpm | 12,560 m3/min | <39 dB | 105 kg | O 35-40 m |
| RDF-H7200 | 7,200 mm (24 ft) | 220V/50Hz, 1-phase | 4.4 A | 1.3 kW | 55 rpm | 15,197 m3/min | <39 dB | 115 kg | O 38-44 m |
| RDF-H7200 | 7,200 mm (24 ft) | 380V/50Hz, 3-phase | 3.0 A | 1.3 kW | 55 rpm | 15,197 m3/min | <39 dB | 115 kg | O 38-44 m |

Airflow at maximum speed per the manufacturer type test; running speed is infinitely variable. The 5.2 m model's printed "14 ft" in the source brochure is a brochure typo; the manufacturer's Chinese-market spec table lists 5.2 m = 17 ft, the correct conversion.

## Retail and public-space installation

Mall atria and hypermarkets over 8 m are typical 6.2-7.2 m installations, often run on BMS schedules tied to opening hours. Standard supermarkets and markets at 4.5-6 m use the 3.6-5.2 m models; the finished fan ships with decorative hub covers so it reads as an architectural fixture rather than industrial equipment.

Wholesale and wet markets gain a practical benefit: the continuous gentle airflow keeps stall areas fresher and reduces stagnant, odorous pockets in crowded aisles without disturbing lightweight goods or signage.

## Backed by a specialist air-treatment manufacturer

- 20+ years focused on evaporative cooling and large industrial fans; National High-Tech Enterprise and CRAA-listed manufacturer.
- Deputy Director Unit of the national evaporative-cooling industry committee, with 40+ patents and self-developed, patented molds.
- Product liability underwritten by CPIC (policy ADNGD0207121Q000109N); type-test, protection-grade and CE motor-conformity documentation supplied with export orders.
- RDF equipment is published in service with automotive, food and electronics manufacturers including SAIC-GM-Wuling, FAW-Volkswagen, GAC Toyota/Honda, PepsiCo, Foxconn, Panasonic, Gree, Midea and Haier.

## Ordering the HVLS fan for shopping malls, markets and exhibition halls

- **MOQ:** 10 units
- **Lead time:** 10 units in about 5 days; 100 units in about 20 days; 500 units in about 60 days - schedule varies by model and production plan, confirmed per order
- **Trade terms:** FOB Shenzhen
- **Payment:** T/T - 35% deposit, 65% balance paid before shipment
- **Warranty:** 2-year warranty on the complete unit per the factory's warranty policy: motor 2 years, controller 2 years. Overseas spare-parts support (wear-parts list, quotation and dispatch lead time) is confirmed with your order.
- **Documentation:** CE conformity reports for the PMSM drive motor (EMC 2014/30/EU, LVD 2014/35/EU), IP-rating report and 7.2 m type-test reports (220 V / 380 V) are available with your order.

Send your floor dimensions, ceiling height and heat-load description (a sketch or photo is enough) - we reply with a model recommendation, layout and quotation within one business day via the [contact page](/contact/).

## Frequently asked questions

### Can customers beneath the fan feel it?

They feel comfortable movement rather than a draught - the defining HVLS effect. Speed presets let management set trading-hours levels versus cleaning/night destratification.

### What safety certification exists above the public?

The fan uses the triple-bolt anti-drop hub, steel petiole and independent safety cable; the 7.2 m model has factory type-test reports at 220 V and 380 V and the motor has CE EMC/LVD conformity documentation. Local structural sign-off follows the site survey.

### Can it run from the building management system?

The standard vector controller accepts speed commands; the IoT option supports group and scheduled control; the manufacturer's control platform uses standard RS485 communication (one master station manages up to 32 units with external temperature/humidity sensors, as deployed on the evaporative-cooler product line) formal protocol mapping and BMS gateway options for export projects are confirmed at quotation stage.

### Does it help the AC actually work in a tall atrium?

That is one of its clearest retail uses: without mixing, cold air drops and hot air stratifies, so upper-floor and ground comfort diverge. The fan equalises the void at a fraction of the cooling kW.

## Related products

- [Large-Diameter HVLS Ceiling Fan](/product/large-diameter-hvls-ceiling-fan/)
- [HVLS Fans for Gyms & Sports Halls](/product/hvls-fans-for-gyms-sports-halls/)
- [7.2 m HVLS Fan (PMSM Direct-Drive)](/product/7-2m-hvls-ceiling-fan-pmsm-direct-drive/)

## More from TierCooling

- [View installed project references](/projects/)
- [About the manufacturer](/about/)
- [All products in this category](/product-category/hvls-ceiling-fans/)

## FAQ

### What does HVLS mean?

High Volume, Low Speed: large-diameter ceiling fans that move a very large air volume at low rotational speed, covering big floor areas with gentle, even airflow instead of concentrated high-speed blasts.

### Why choose a PMSM direct-drive HVLS fan?

Permanent-magnet synchronous motors with direct drive run at high efficiency with fewer wearing parts than geared designs - meaning lower energy use, quieter operation and less maintenance over the fan's life.

### Which sites use HVLS ceiling fans?

Typical applications include factories, warehouses, gyms and sports halls, markets and malls, playgrounds and sports fields, and livestock farms - any large space where uniform airflow and lower energy cost matter.

### How is fan size and unit count decided?

Selection comes from floor area, mounting height and the obstruction layout of the site; suppliers model diameter and placement from drawings so airflow reaches working zones evenly.