Semi-outdoor sports venues – covered futsal courts, school playground canopies, grandstands and stadium concourses – sit in the hardest environment for comfort cooling: open sides, heat radiating from roofs, crowds in bursts. RDF HVLS fans for playgrounds and sports fields move up to 15,197 m3/min over the covered zone using an IP64 gearless drive rated for dust and splash, at under 39 dB(A).
Why projects specify this RDF HVLS fan
- IP64 sealed, gearless motor tolerates the dust, rain splash and humidity of open-sided covered venues.
- ~1,450 m2 per 1.3 kW fan makes canopy-level coverage of courts and spectator zones viable where ducted AC never could be.
- Low-speed safety profile above active play areas, with triple-bolt anti-drop hub and safety cable.
- Comfort for intermittent crowds – switch on before events; disperse venue heat that builds under metal roofs all afternoon.
- Both 220 V and 380 V versions to match municipal school or stadium power supplies.
Technical specifications
| Model | Diameter | Power supply | Current | Power | Max. speed | Max. airflow | Noise | Net weight | Coverage |
|---|---|---|---|---|---|---|---|---|---|
| RDF-S3600 | 3,600 mm (12 ft) | 220V/50Hz, 1-phase | 3.0 A | 0.66 kW | 90 rpm | 4,522 m3/min | <38 dB | 72 kg | O 20-24 m |
| RDF-S4200 | 4,200 mm (14 ft) | 220V/50Hz, 1-phase | 3.0 A | 0.66 kW | 80 rpm | 5,306 m3/min | <38 dB | 75 kg | O 22-26 m |
| RDF-S5200 | 5,200 mm (17 ft*) | 220V/50Hz, 1-phase | 3.0 A | 0.66 kW | 70 rpm | 7,065 m3/min | <39 dB | 78 kg | O 25-30 m |
| RDF-B6200 | 6,200 mm (20 ft) | 220V/50Hz, 1-phase | 4.4 A | 1.3 kW | 65 rpm | 10,747 m3/min | <39 dB | 100 kg | O 32-37 m |
| RDF-B6200 | 6,200 mm (20 ft) | 380V/50Hz, 3-phase | 3.0 A | 1.3 kW | 65 rpm | 10,747 m3/min | <39 dB | 100 kg | O 32-37 m |
| RDF-B6700 | 6,700 mm (22 ft) | 220V/50Hz, 1-phase | 4.4 A | 1.3 kW | 60 rpm | 12,560 m3/min | <39 dB | 105 kg | O 35-40 m |
| RDF-B6700 | 6,700 mm (22 ft) | 380V/50Hz, 3-phase | 3.0 A | 1.3 kW | 60 rpm | 12,560 m3/min | <39 dB | 105 kg | O 35-40 m |
| RDF-H7200 | 7,200 mm (24 ft) | 220V/50Hz, 1-phase | 4.4 A | 1.3 kW | 55 rpm | 15,197 m3/min | <39 dB | 115 kg | O 38-44 m |
| RDF-H7200 | 7,200 mm (24 ft) | 380V/50Hz, 3-phase | 3.0 A | 1.3 kW | 55 rpm | 15,197 m3/min | <39 dB | 115 kg | O 38-44 m |
Airflow at maximum speed per the manufacturer type test; running speed is infinitely variable. The 5.2 m model’s printed “14 ft” in the source brochure is a brochure typo; the manufacturer’s Chinese-market spec table lists 5.2 m = 17 ft, the correct conversion.
Semi-outdoor design considerations
These installations are engineered as covered-environment fans, not weather-exposed units: the IP64 motor tolerates splash and dust but the fan should remain under a permanent canopy with the electrical connection made to outdoor-rated local code. Grandstands, swimming-pool enclosures and covered play courts are the typical scope.
Layout follows the shade structure: 6.2-7.2 m fans under high canopy roofs (8-15 m), 4.2-5.2 m units under lower school walkway and play-shelter roofs. We recommend confirming wind exposure and mounting structure with our engineering drawing before ordering for coastal or high-wind sites wind-load assessment documentation can be arranged for export projects upon request.
Backed by a specialist air-treatment manufacturer
- 20+ years focused on evaporative cooling and large industrial fans; National High-Tech Enterprise and CRAA-listed manufacturer.
- Deputy Director Unit of the national evaporative-cooling industry committee, with 40+ patents and self-developed, patented molds.
- Product liability underwritten by CPIC (policy ADNGD0207121Q000109N); type-test, protection-grade and CE motor-conformity documentation supplied with export orders.
- RDF equipment is published in service with automotive, food and electronics manufacturers including SAIC-GM-Wuling, FAW-Volkswagen, GAC Toyota/Honda, PepsiCo, Foxconn, Panasonic, Gree, Midea and Haier.
Ordering the HVLS fan for playgrounds, sports fields and covered venues
- MOQ: 10 units
- Lead time: 10 units in about 5 days; 100 units in about 20 days; 500 units in about 60 days – schedule varies by model and production plan, confirmed per order
- Trade terms: FOB Shenzhen
- Payment: T/T – 35% deposit, 65% balance paid before shipment
- Warranty: 2-year warranty on the complete unit per the factory’s warranty policy: motor 2 years, controller 2 years. Overseas spare-parts support (wear-parts list, quotation and dispatch lead time) is confirmed with your order.
- Documentation: CE conformity reports for the PMSM drive motor (EMC 2014/30/EU, LVD 2014/35/EU), IP-rating report and 7.2 m type-test reports (220 V / 380 V) are available with your order.
Send your floor dimensions, ceiling height and heat-load description (a sketch or photo is enough) – we reply with a model recommendation, layout and quotation within one business day via the contact page.
Frequently asked questions
Can the fan be installed outdoors?
It is IP64 rated for dust and splash and intended for covered or semi-outdoor spaces – a permanent roof or canopy is required. It is not rated for direct rain exposure or free-standing pole mounting.
Does wind interfere with it?
In open-sided venues cross-winds alter the local air pattern but do not harm the fan; structure and controller are designed for normal building wind conditions. High-wind regions require a structural check, which we support with mounting drawings.
How many fans does a covered five-a-side pitch need?
Typically one 7.2 m fan covers the court zone from a 9-12 m canopy; two 6.2-6.7 m units are used where the roof is lower or the pitch spans two bays. A canopy drawing is enough for a layout proposal.
What power supply do school venues use?
Both 220 V single-phase and 380 V three-phase are available from 6.2 m upward; municipal venues more often have three-phase, smaller school canopies single-phase.
Related products
- HVLS Fans for Gyms & Sports Halls
- 7.2 m HVLS Fan (PMSM Direct-Drive)
- Portable Evaporative Air Cooler (18Y/20H)
More from TierCooling
FAQ
What does HVLS mean?
High Volume, Low Speed: large-diameter ceiling fans that move a very large air volume at low rotational speed, covering big floor areas with gentle, even airflow instead of concentrated high-speed blasts.
Why choose a PMSM direct-drive HVLS fan?
Permanent-magnet synchronous motors with direct drive run at high efficiency with fewer wearing parts than geared designs – meaning lower energy use, quieter operation and less maintenance over the fan’s life.
Which sites use HVLS ceiling fans?
Typical applications include factories, warehouses, gyms and sports halls, markets and malls, playgrounds and sports fields, and livestock farms – any large space where uniform airflow and lower energy cost matter.
How is fan size and unit count decided?
Selection comes from floor area, mounting height and the obstruction layout of the site; suppliers model diameter and placement from drawings so airflow reaches working zones evenly.






Reviews
There are no reviews yet.